DEHN Safety Equipment
Success needs Safety


No Accident happens
out of the Blue!
Safety begins in mind.
Average Expenses
Electricity is great. Our modern industrial and
communication society with all its possibilities
for Payments of Compensation
would be completely unimaginable without it.
However, nothing has only advantages, there are
per Accident*
also disadvantages. The human being is a user of
electrical energy, but, unfortunately, does not
have any sense organs to perceive it and did not
form any natural reflexes to protect itself against
the possible hazards of electrical energy.
23,000
By forming and using its knowledge, adapting
its behaviour and by using the right equipment,
it must compensate for this evolutionary deficit.
Standards
7,500
EN 50110-1
Operation of electrical
installations
HD 637 S1
Power installations
2,500
exceeding 1 kV
IEC 61230
Live working - Portable
equipment for earthing or
earthing and short-circuiting
General
Accidents on the way
Accidents caused
IEC 61243-1
Live working - Voltage
occupational
from/to the workplace
by electricity
detectors - Part 1
accidents
Capacitive type to be used
for voltages exceeding
1 kV a.c.
* Ref.: Hans-Heinrich Egyptien: Check für mehr Arbeitssicherheit, Chancen in der Elektrobranche 1999, Verlag Technik Berlin 1999
IEC 61243-5
Live working - Voltage
detectors - Part 5
Occupational safety is a social concern.
Voltage Detecting Systems
Amongst others, international and national health
There is no second chance
IEC 60832
Insulating poles
and safety regulations, national legislation and
(insulating sticks) and
for carelessness.
universal tool attachments
generally approved technical rules have great in-
(fittings) for live working
Carelessness, excessive demand and lack of concentration
DEHN + SÖHNE have a vast experience in the field of
fluence on occupational safety.
are the causes of many accidents that could have been
operational safety and want to help you to make your
IEC 60895
Conductive clothing for live
avoided. Consequences are personnel accidents, operational
company fit for the future operational safety requirements.
working at a nominal
Providing occupational safety is the
voltage up to 800 kV a.c.
downtimes, destroyed equipment and environmental
management's task.
damage. The expenses and also image losses for a company
IEC 60903
Specification for gloves and
Every employer bears the total responsibility for
can often not be compensated for. Accidents with electricity
mitts of insulating material
for live working
safety and health protection within the company.
cause considerably higher costs than other operational
This, however, cannot be delegated as a whole.
accidents. For avoiding accidents, it is mandatory to observe
IEC 60984
Sleeves of insulating
The entrepreneur can only involve the executives
laws and safety regulations. Working at electrical systems
material for live working
in this responsibility. Apart from the professional
and equipment should only be carried out by qualified
responsibility, every manager must thus bear the
electricians or by persons under qualified supervision.
responsibility for the safety of his employees.












O L D N E W
Safety can be achieved
>hazardous<
>safe<
Dead Working.
Even if all necessary
precautions are taken
No matter what kind of work to be
carried out, operational safety is
More safety is required.
always ensured, if the potential
If there is still a failure and in order
hazard is eliminated or reduced for
to avoid any subsequential damage,
the person involved. Since the
the electrical systems worked on
beginning of using electrical energy,
Do not leave vital
must be earthed and short-circuited.
the relevant parts of the system
information to chance.
However, this measure is also only
have therefore been disconnected
Independent from its operating
as good as the equipment used for
from the power supply when work
state, every electrical system and
these purposes.
had to be carried out on electrical
equipment must principally be
systems and equipment.
Ravages of time leave their marks
regarded as energised until it is
here as well. Corrosion can reduce
For disconnecting a system and
proved to be dead.
the effective cross section of earth-
finally giving permission to work,
Therefore, the voltage detectors
ing and short-circuiting cables
reliable information is needed re-
used must provide reliability and
and thus question safety.
garding the state of the installation,
perceptibility of indication and the
This is not the case with earthing
measures to be taken for avoiding
necessary electrical safety for the
and short-circuiting devices tested
maloperations or malfunctions as
user. This applies to both the test
in accordance with the current
well as information about protection
procedure and the test result.
requirements of IEC 61230.
against upcome maloperations or
Both must be reliable.
Here, DEHN + SÖHNE is your
malfunctions and protection against
Test equipment produced decades
reliable partner.
potential hazards from adjacent
ago is hardly capable of fulfilling
parts of the installation. In order
the safety requirements of today.
to avoid the above harzards, the
Additionally, the switchgears of
5 common safety rules have been
today require only an eighth of the
formulated:
I
space needed for switchgears pro-
Disconnect completely
I
duced 30 years ago. Thus, the safety
Secure against re-connection
I
requirements for test equipment
Verify that the installation
must be upgraded.
is dead
I
More compact system constructions
Carry out earthing and
require shorter distances between
short-circuiting
I
the live parts within those systems.
Provide protection against
Furthermore, these setups increase
adjacent live parts
the variety of interferences on the
Every electrician is familiar with
test equipment used. Therefore,
these rules as a life insurance.
the demand for the utilisation of
But what about the safety and
operational equipment in accor-
reliability of the devices and
dance with the generally approved
equipment providing this vital
technical rules, is not made without
information?
reason. Devices for operating,
Information is only as safe as the
testing and safeguarding live parts
technologies used for obtaining it.
with nominal voltages exceeding
1,000 V must therefore always
correspond to the current require-
ments of IEC standards.
For the safety of your colleagues
and employees and for your own
safety, DEHN + SÖHNE offers you
the right equipment.









Perceive your Risk and
you can eliminate it.
Live Working
Nowadays, with international competition, permanent
availability of electrical energy has become an important
factor. At the same time, the increasing competition on
the power supply market prompts the facilities to reduce
more and more their provisions of excess capacities of
FRS ZK MS Damp Cleaning Set
power supply. Firstly, this requires an increased operational
safety of existing systems. Secondly, some parts of the
TRS MS Dry Cleaning Set
system cannot be disonnected completely during the
required maintenance and repair procedures.
For these purposes, live working is a good solution.
Basically, the following methods can be applied:
I Hot Stick Working Safe Clearance Working
TRS NS Dry Cleaning Set
I Insulating Glove Working Rubber Glove Working
I Bare Hand Working
TFRS MS Combined Cleaning Set
Because of the high skill requirements of live working,
this kind of work may only be done by qualified elec-
tricians or professionally instructed persons.
The advantages of this working method are obvious:
I Increased reliability of power supply
I Uninterrupted power supply for the customer.
Better rating of your industrial customers.
Before Cleaning
I Cost reduction
After Cleaning
I No more switching operations
I No more coordination work for customer
and supplier
I Independent timing for carrying out the work
Cleaning
European standards provide a safety-related equalisation
of dead working and live working.
With the brand DELTEC®, DEHN + SÖHNE offers a wide
range of devices and equipment for this working method.